E-062 Tattoo Removal Nd-Yag Laser Device
$1,800.00
FEATURES AND ADVANTAGES
1.Innovative in technology, strict in technicaldetection, precise in manufacture, stable and effective in performance.
2.Special designed cooling system ensures constantly working.
3.Micro Computer counts the shoots.
4.Portable and aseismatic, convenient for transportation.
5.user friendly interface with LCD display
6.No injury to normal tissue.
7.Remove pigmentation without side effects or scar.
8.Short Operation period with outstanding effect.
Description
WORKING THEORY
ND: YAG Cosmetic System introduces gem-adjusting Q-switch, which uses high energy by instant emission of beam to crush and remove the pigment effectively in the pathologically changed tissues. That is an explosion led by beam: the beam at the fixed wavelength enabled by the accumulated high energy can reach the pathologically changed tissues through epidermis in a very short time (only 6 ns) to instantly crush the respective colour base, then the corresponding pigment group gets swollen and outburst at last due to high energy, and part of the pigment group springs out of the human body (at shallow epidermis), and the rest (at basis tissues) pigment group will become very small particle before swallowed by the human cell which will be finally discharged out of the human body through lymphatic system circulation.The pigment of the pathological tissues will fade in colour till it vanishes.And the surrounding normal tissues will not be ruined since they will not absorb the at that fixed wavelength.
APPLICATION
The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery,lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source,freckle on female’s face (male’s), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Operation course for different illness case as follows:
(1)Operation for tattoo in eyebrow
Customer could not open eyes during Operation , operator should adjust energy according to depth of tattoo colour, hold the handle and move it to Operation area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to Operation area, start Operation from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the colour of tattoo re-appear.
(2)Remove eye line
The speed of flashes could be set 4-5HZ, adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and Operation treatment area. Operator should strictly protect customers` eyes with panel for eyelid or medical pledget (panel for eyelid)of 25px depth.
Operation should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eyeline. Also customer should close eyes and keep eyeball down-sight inside.Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.
(3)Remove lip line
The speed of flashes could be set 5Hz,keep a 3/4 finger distance betweenhead of handle and Operation area. It is better to remove black, coffee, deep,red and brown lip line with 1064 head at first time and then, treat again with532 head.
Notice: All tattoos in lip should be treated in 6 months after making. Or removal Operation will fail. It should have 45-60 days interval to continue next Operation until remove all.
(4)Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use highenergy for Operation until Operation area seeps a little blood. It should have45-90 days interval to continue next Operation until remove all.
(5)Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz. Keep 3-4 fingers distance between head of handle and Operation area. It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for normal spot and nevus Operation , but for deep colour spot and nevus, it is better to use 532 head for Operation . It should have a 15-30 days interval to continue next Operation until remove all.
(6)Remove birthmark
The speed of flashes could be set 3Hz/5Hz. It is better to use high energy for Operation until treat Operation area seeps a little blood. It is advised to use 1064 head for birthmark Operation , but for red and deep colour birthmark, it is better to use 532 head for Operation . It should have 45-90 days interval to continue
PRODUCT SHOW
PRODUCT DETAILS
FEATURES AND ADVANTAGES
1.Innovative in technology, strict in technicaldetection, precise in manufacture, stable and effective in performance.
2.Special designed cooling system ensures constantly working.
3.Micro Computer counts the shoots.
4.Portable and aseismatic, convenient for transportation.
5.user friendly interface with LCD display
6.No injury to normal tissue.
7.Remove pigmentation without side effects or scar.
8.Short Operation period with outstanding effect.
PARAMETERS
Cooling condition: wind system+closed circulating+cooling system
Laser type: Q-switch Nd: YAG
With RED target light to aim at the skin.
The pulse energy: 0~1000mJ
Pulse width: 6ms
Recurrence rate: 1, 2, 3, 4, 5, 6Hz
Power source: 110v~220v